[PATCH 2/3] tools/power turbostat: Restore u32 truncation for raw counters

From: Qinyun Tan

Date: Mon Nov 23 2026 - 22:27:35 EST


The u32 size option truncates raw counter values to 32 bits for display.
However, print_hex_value() now prints the full value even when the width
is 32 bits. For example, 0x000000edc994ba0d is printed as edc994ba0d
instead of c994ba0d.

The print helper cleanup replaced %08x and the unsigned int cast with
%08llx. The field width is a minimum, so it does not truncate values
that need more than eight hexadecimal digits. The cast was needed to
discard the upper 32 bits.

Restore the cast and %08x for raw counters up to 32 bits wide. Leave
64-bit raw values and decimal counter formatting unchanged.

Fixes: 092b76a3253f ("tools/power turbostat: Cleanup print helper functions")
Signed-off-by: Qinyun Tan <qinyuntan@xxxxxxxxxxxxxxxxx>
---
tools/power/x86/turbostat/turbostat.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/tools/power/x86/turbostat/turbostat.c b/tools/power/x86/turbostat/turbostat.c
index 4e7eba8d8752..d0f0b4af6094 100644
--- a/tools/power/x86/turbostat/turbostat.c
+++ b/tools/power/x86/turbostat/turbostat.c
@@ -2906,7 +2906,7 @@ static inline int print_hex_value(int width, int *printed, char *delim, unsigned
char *sep = (*printed)++ ? delim : "";

if (width <= 32)
- return sprintf(outp, "%s%08llx", sep, value);
+ return sprintf(outp, "%s%08x", sep, (unsigned int)value);
else
return sprintf(outp, "%s%016llx", sep, value);
}
--
2.55.0