Re: [PATCH 0/2] iio: chemical: Add driver and bindings for acd10

From: Andy Shevchenko

Date: Mon Nov 23 2026 - 04:28:53 EST


On Sun, Nov 22, 2026 at 06:30:43AM +0000, Akhilesh Patil wrote:
> This patch series adds support for Aosong ASAIR acd10 CO2 (Carbon
> dioxide) sensor driver in IIO subsystem.

There is no answer to the question "Why a brand new driver?"

> Patch 1: Adds bindings for this hardware
> Patch 2: Adds driver code for acd10 under drivers/iio/chemical
>
> Quick overview of acd10:
> - This is CO2 sensor based on NDIR technology.
> - Can measure CO2 concentration up to 5000ppm
> - Supports serial interface over UART with 1200 baud rate.
>
> Datasheet: https://www.es.co.th/Schemetic/PDF/ACD10.PDF
>
> Protocol:
> acd10 defines 4 types of UART frames - read co2, get software version,
> get instrument number and set single point calibration.
> Frame format: fixed header, length of data, command code, Actual data,
> checksum. Response from the sensor follows same format.
> Total length of each tx and rx frame for 4 commands is fixed and defined in
> the datasheet. Driver uses this information to write and read from
> sensor for each command over serdev interface.
>
> Testing:
> Driver is tested on Texas Instruments am62x sk board with sensor
> connected on UART5 on 40pin IO expander. Additional 3.3 to 5v
> bidirectional logic translator is used to interface with 3.3v IOs of
> am62x. Values are read using iio sysfs interface. Also I have blown into
> the sensor to observe sensor output increase due to CO2 in my exhale.
> Waveforms for read co2, get sw rev and get ins num commands are
> validated on logic analyzer.
>
> Slight deviation from datasheet:
> For command get software version, datasheet mentions frame length of 16
> bytes including D11 reserved, however it is observed that sensor sends
> 15 bytes with length field 0xb (11 bytes of data), but actual data is 10
> bytes. Hence, this is handled in the driver.
>
> Driver supports reading co2, getting sw version and instrument number.
> Single point calibration and preheat implementation is left for
> future contributions.

--
With Best Regards,