[PATCH 0/2] serial: amba-pl011: fix RS485 state on enable and reconfiguration

From: Nicolai Buchwitz

Date: Fri Oct 16 2026 - 03:39:14 EST


More RS485 fixes for pl011, on top of the ones already in tty-next.
Together they are the groundwork for a series I plan to send next
cycle, which refactors the RS485 code for better performance and
reliability.

Both patches fix changing the RS485 settings while data is going out.
Patch 1 keeps the transceiver from driving the bus after the data is
out when RS485 is enabled mid-transmission. Patch 2 keeps a
reconfiguration from stalling the port.

---
Nicolai Buchwitz (2):
serial: amba-pl011: finish a transmission still running when RS485 is enabled
serial: amba-pl011: keep RS485 transmission running on reconfiguration

drivers/tty/serial/amba-pl011.c | 54 +++++++++++++++++++++++++++++++++++++++--
1 file changed, 52 insertions(+), 2 deletions(-)
---
base-commit: 1184f87e2790e8af9be3116f608d2e86b4792d7d
change-id: 20261016-devel-nbuchwitz-pl011-rs485-reconfig-stall-f4fe437cccae

Best regards,
--
Nicolai Buchwitz <nb@xxxxxxxxxxx>