[PATCH v6 1/8] dt-bindings: iio: light: vcnl4000: add regulators

From: Erikas Bitovtas

Date: Fri Mar 20 2026 - 13:07:39 EST


These sensors can accept 2 supplies - one for the sensor and one for IR
LED [1]. Add supply properties for the sensor - 2 for the sensors and
one external, for their open drain interrupt line, to ensure the sensor
is powered on before proceeding with setup.

[1] https://www.vishay.com/docs/84274/vcnl4040.pdf

Reviewed-by: David Lechner <dlechner@xxxxxxxxxxxx>
Signed-off-by: Erikas Bitovtas <xerikasxx@xxxxxxxxx>
---
.../devicetree/bindings/iio/light/vishay,vcnl4000.yaml | 14 ++++++++++++++
1 file changed, 14 insertions(+)

diff --git a/Documentation/devicetree/bindings/iio/light/vishay,vcnl4000.yaml b/Documentation/devicetree/bindings/iio/light/vishay,vcnl4000.yaml
index 2ba4d5de4ec4..516afef7a545 100644
--- a/Documentation/devicetree/bindings/iio/light/vishay,vcnl4000.yaml
+++ b/Documentation/devicetree/bindings/iio/light/vishay,vcnl4000.yaml
@@ -33,6 +33,17 @@ properties:
interrupts:
maxItems: 1

+ vdd-supply:
+ description: Regulator providing power to the "VDD" pin.
+
+ vio-supply:
+ description: Regulator providing power for pull-up of the I/O lines.
+ Does not connect to the sensor directly, but is needed for the
+ correct operation of the I2C and interrupt lines.
+
+ vled-supply:
+ description: Regulator providing power to the IR anode pin.
+
reg:
maxItems: 1

@@ -54,6 +65,9 @@ examples:
compatible = "vishay,vcnl4200";
reg = <0x51>;
proximity-near-level = <220>;
+ vdd-supply = <&reg_vdd>;
+ vio-supply = <&reg_vio>;
+ vled-supply = <&reg_vled>;
};
};
...

--
2.53.0